Miele appliance error codes generally fall into several categories, each indicating a different type of issue. For instance, some codes may point to electrical problems, while others may indicate mechanical issues or user errors. Recognising the category of the error code can significantly narrow down the potential causes of the problem.
It is important to understand that although certain error codes can be resolved through do-it-yourself methods, there are instances where professional assistance may be necessary. Recognising the appropriate time to contact our skilled Miele technicians is essential in order to preserve the functionality and reliability of your appliance.
Need assistance?
Call us now on 0115 961 3720 to book an engineer. We’re always here to help
List of Miele Error Codes
Model: 5425/26
Error Code | Error |
PRE-WASH | LED (0.1ON 0.1OFF) LEVEL SWITCH FAULT |
MAIN WASH | LED (0.1ON 0.1OFF) NTC FAULT |
MAIN WASH | LED (0.1ON 0.1OFF) CORRECT TEMP NOT REACHED DURING THERMOSTOP |
RINSE | LED (0.1ON 0.1OFF) TACHOGENERATOR FAULT CHECK MOTOR CARBONS/WIRING |
TAP/RED | LED (0.1ON 0.1OFF) SLOW FILL CHECK FILTERS/ UP FILL TIME SEE PROG MODE1 (5/9) |
DRAIN/RED | LED (0.1ON 0.1OFF) SLOW DRAIN CHECK PUMP/D VALVE DRAIN BLOCKAGE |
LED ON/START | LED (0.5ON 0.5OFF) SELECTED PROG CHANGED DURING PROG LED WILL STOP FLASHING WHEN PROG AT THE START IS RESECLECTED, WHICH NORMALLY IS ( SLUICE PROG )SELECT IN ERROR (CHECKPROG SWITCH CAM MAYBE FAULTY) A SLUICE PROG CAN ONLY BE ENDED DURING THE WASH BY ADDING A FAULT OR RESET POWER BOARD PLUG 2 WIRE WITH LINK (IF FITTED) |
LED PRE-WASH | LED (0.5 ON 0.5OFF) - SERVICE MODE |
PRE +MAIN WASH | LED (0.5 ON 0.5OFF) - PROGRAMMING MODE 1 / 2 |
MAIN WASH | LED (0.5 ON 0.5OFF) - PROGRAMMING MODE 3 |
LED STARCH | LED (0.5 ON 0.5OFF) - REMINDER TO ADD STARCH |
LED DRAIN | LED (0.5 ON 0.5OFF) - RINSE HOLD |
LED PROG SEQ | LED (0.5 ON 0.5OFF) TIME EXPIRED WITH COIN MECHANISM |
Model: PW
Error Code | Error |
F0 | * NO FAULTS LISTED IN HISTORY |
F1 | * NTC FAULT CHECK RESISTANCE, & OPEN OR SHORT CIRCUIT THE |
F2 | * CHECK AS ABOVE F1 |
F10 | DISPLAY= WATER INLET FAULT SLOW FILL,TIME CAN BE EXTENDED VIA |
F11 | DISPLAY=WATER DRAINAGE FAULT CHECK DRAIN PUMP/ VALVE/ DRAINES |
F15 | * HOT INLET FAULT PROGRAMME CONTINUES WITH COLD WATER |
F16 | DISPLAY=AT THE END OF THE PROGRAMME =EXCESS FOAM (OVER SOAP) |
F20 | * HEATING THE CORRECT TEMPERATURE HAS NOT BEEN REACHED |
F41 | EEPROM/ DATA FAULT DISPLAY= TECHNICAL FAULT PROGRAMME IS INTERRUPTED(REPLACE POWER-PROGRAMME MODULE (ELP) |
F43 | MODEL TYPE NOT PROGRAMMED DISPLAY= TECHNICAL FAULT THE SELECTION MODULE (EW) AND THE POWER-PROGRAMME MODULE (ELP) DO NOT MATCH CHECK MAT. NOS.TO VERIFY CORRECT SELECTION |
F44 | DISPLAY=TECHNICAL FAULT I 2 C BUS CONNECTION FAULTY PROGRAMME IS INTERRUPTED REPLACED (ELP) MODULE |
F45 | FAULTY FLASH RAM/INCORRECT DATA CHECK MAT.NOS.TO VERIFY THAT THE CORRECT SELECTION MODULE(EW) AND POWER-PROGRAMMED MODULE (EPL,) ARE FITTED USE THE RESET PROGRAMME FUNCTION TO TO RESET ALL STANDARD SETTINGS THEN REPROGRAMME/ REPLACED(ELP) |
F46 | DISPLAY FAULT (EW) LCD DRIVER DEFECTIVE REPLACE (EW) |
F47 | (EW)-POWER-PROGRAMME MODULE (ELP) INTERFACE FAULT CHECK CONNECTIONS BETWEEN (EW) AND THE (ELP) MODULE |
F50 | DISPLAY=TECHNICAL FAULT DRIVE FAULT MOTOR/INVERTER FAULT |
F51 | DISPLAY=TECHNICAL FAULT ANALOG PRESSURE SENSOR(ADS) FAULT PRESSURE SENSOR INTEGRATED IN THE (ELP) MODULE |
F53 | DISPLAY=TECHNICAL FAULT TACHOGENERATOR DEFECTIVE/WIRING |
F56 | NO SPIN ,SPIN SPEED<400 RPM SELECTED SPIN ABOVE 450 RPM SEE F16 |
F63 | DISPLAY=TECHNICAL FAULT WATER PATH CONTROL FAULTY(FILL FAULT ?) |
F65 | DRUM LIGHTING CAP MISSING DISPLAY =DRUM LIGHTING |
Model: PT
Error Code | Error |
F0 | NO FAULTS |
F1 | HEATER BANK NTC SHORT CIRCUIT |
F2 | HEATER BANK NTC OPEN CIRCUIT |
F3 | FILL RING NTC SENSOR SHORT CIRCUIT |
F4 | FILL RING NTC SENSOR OPEN CIRCUIT |
F41 | FAULTY EEPROM/DATA FAULT |
F43 | MODEL TYPE NOT PROGRAMMED |
F45 | FAULTY FLASH RAM/DATA FAULT |
F46 | DISPLAY FAULT |
F47 | COMM'S FAULT BETWEEN EW/ELP ELECTRONIC MODULES |
F50 | MOTOR STATIONARY & HEATING OPERATES FOR 5,SEC |
F55 | OVERRIDING TIME LIMIT EXCEEDED |
F66 | AIR LEAKAGE FAULT |