Error Codes for Miele

Miele appliance error codes generally fall into several categories, each indicating a different type of issue. For instance, some codes may point to electrical problems, while others may indicate mechanical issues or user errors. Recognising the category of the error code can significantly narrow down the potential causes of the problem.

It is important to understand that although certain error codes can be resolved through do-it-yourself methods, there are instances where professional assistance may be necessary. Recognising the appropriate time to contact our skilled Miele technicians is essential in order to preserve the functionality and reliability of your appliance.

Error Codes for Miele

Need assistance?

Call us now on 0115 961 3720 to book an engineer. We’re always here to help

List of Miele Error Codes

Model: 5425/26

Error CodeError
PRE-WASHLED (0.1ON 0.1OFF) LEVEL SWITCH FAULT
MAIN WASHLED (0.1ON 0.1OFF) NTC FAULT
MAIN WASHLED (0.1ON 0.1OFF) CORRECT TEMP NOT REACHED DURING THERMOSTOP
RINSELED (0.1ON 0.1OFF) TACHOGENERATOR FAULT CHECK MOTOR CARBONS/WIRING
TAP/REDLED (0.1ON 0.1OFF) SLOW FILL CHECK FILTERS/ UP FILL TIME SEE PROG MODE1 (5/9)
DRAIN/REDLED (0.1ON 0.1OFF) SLOW DRAIN CHECK PUMP/D VALVE DRAIN BLOCKAGE
LED ON/STARTLED (0.5ON 0.5OFF) SELECTED PROG CHANGED DURING PROG LED WILL STOP FLASHING WHEN PROG AT THE START IS RESECLECTED, WHICH NORMALLY IS ( SLUICE PROG )SELECT IN ERROR (CHECKPROG SWITCH CAM MAYBE FAULTY) A SLUICE PROG CAN ONLY BE ENDED DURING THE WASH BY ADDING A FAULT OR RESET POWER BOARD PLUG 2 WIRE WITH LINK (IF FITTED)
LED PRE-WASHLED (0.5 ON 0.5OFF) - SERVICE MODE
PRE +MAIN WASHLED (0.5 ON 0.5OFF) - PROGRAMMING MODE 1 / 2
MAIN WASHLED (0.5 ON 0.5OFF) - PROGRAMMING MODE 3
LED STARCHLED (0.5 ON 0.5OFF) - REMINDER TO ADD STARCH
LED DRAINLED (0.5 ON 0.5OFF) - RINSE HOLD
LED PROG SEQLED (0.5 ON 0.5OFF) TIME EXPIRED WITH COIN MECHANISM

Model: PW

Error CodeError
F0* NO FAULTS LISTED IN HISTORY
F1* NTC FAULT CHECK RESISTANCE, & OPEN OR SHORT CIRCUIT THE
F2* CHECK AS ABOVE F1
F10DISPLAY= WATER INLET FAULT SLOW FILL,TIME CAN BE EXTENDED VIA
F11DISPLAY=WATER DRAINAGE FAULT CHECK DRAIN PUMP/ VALVE/ DRAINES
F15* HOT INLET FAULT PROGRAMME CONTINUES WITH COLD WATER
F16DISPLAY=AT THE END OF THE PROGRAMME =EXCESS FOAM (OVER SOAP)
F20* HEATING THE CORRECT TEMPERATURE HAS NOT BEEN REACHED
F41EEPROM/ DATA FAULT DISPLAY= TECHNICAL FAULT PROGRAMME IS INTERRUPTED(REPLACE POWER-PROGRAMME MODULE (ELP)
F43MODEL TYPE NOT PROGRAMMED DISPLAY= TECHNICAL FAULT THE SELECTION MODULE (EW) AND THE POWER-PROGRAMME MODULE (ELP) DO NOT MATCH CHECK MAT. NOS.TO VERIFY CORRECT SELECTION
F44DISPLAY=TECHNICAL FAULT I 2 C BUS CONNECTION FAULTY PROGRAMME IS INTERRUPTED REPLACED (ELP) MODULE
F45FAULTY FLASH RAM/INCORRECT DATA CHECK MAT.NOS.TO VERIFY THAT THE CORRECT SELECTION MODULE(EW) AND POWER-PROGRAMMED MODULE (EPL,) ARE FITTED USE THE RESET PROGRAMME FUNCTION TO TO RESET ALL STANDARD SETTINGS THEN REPROGRAMME/ REPLACED(ELP)
F46DISPLAY FAULT (EW) LCD DRIVER DEFECTIVE REPLACE (EW)
F47(EW)-POWER-PROGRAMME MODULE (ELP) INTERFACE FAULT CHECK CONNECTIONS BETWEEN (EW) AND THE (ELP) MODULE
F50DISPLAY=TECHNICAL FAULT DRIVE FAULT MOTOR/INVERTER FAULT
F51DISPLAY=TECHNICAL FAULT ANALOG PRESSURE SENSOR(ADS) FAULT PRESSURE SENSOR INTEGRATED IN THE (ELP) MODULE
F53DISPLAY=TECHNICAL FAULT TACHOGENERATOR DEFECTIVE/WIRING
F56NO SPIN ,SPIN SPEED<400 RPM SELECTED SPIN ABOVE 450 RPM SEE F16
F63DISPLAY=TECHNICAL FAULT WATER PATH CONTROL FAULTY(FILL FAULT ?)
F65DRUM LIGHTING CAP MISSING DISPLAY =DRUM LIGHTING

Model: PT

Error CodeError
F0NO FAULTS
F1HEATER BANK NTC SHORT CIRCUIT
F2HEATER BANK NTC OPEN CIRCUIT
F3FILL RING NTC SENSOR SHORT CIRCUIT
F4FILL RING NTC SENSOR OPEN CIRCUIT
F41FAULTY EEPROM/DATA FAULT
F43MODEL TYPE NOT PROGRAMMED
F45FAULTY FLASH RAM/DATA FAULT
F46DISPLAY FAULT
F47COMM'S FAULT BETWEEN EW/ELP ELECTRONIC MODULES
F50MOTOR STATIONARY & HEATING OPERATES FOR 5,SEC
F55OVERRIDING TIME LIMIT EXCEEDED
F66AIR LEAKAGE FAULT