Navigating the complex world of error codes for Primus laundry equipment can be daunting. As crucial as these machines are for efficient laundry operations, encountering error codes can bring everything to a halt. This guide is meticulously designed to demystify the error codes associated with Primus washing machines and dryers. By providing clear explanations and actionable solutions, we aim to empower homeowners, facility managers, and technicians with the knowledge to quickly diagnose and resolve issues. This ensures the continued optimal performance of your Primus laundry appliances.
Error Codes for Primus

Need assistance?

Call us now on 0115 961 3720 to book an engineer. We’re always here to help

List of Primus Error Codes

Model: X

Error CodeError
99DOOR CAN NOT BE OPENED AS THE SAFETY CONDITIONS ARE NOT FULFILLED
1DRAINING
2DRAINING LAST STEP
3START SPIN
4AFTER 10X TILT
5OUT OF BALANCE:HIGH SPIN (>500 OR 750 RPM)
6DOOR SWITCH FAILURE (WHOLE CYCLE)
7DOOR SOLENOID SWITCH FAILURE (WHOLE CYCLE)
8DOORLOCK CHECK AT START FAILURE (AT START UP)
9DOOR LOCK SWITCH CLOSE FAILURE (END CYCLE)
10BIMETAL 2MIN 30,SEC (AFTER START CYCLE)
11FILL FAILURE (WHILE FILLING)
12OVERFILL FAILURE (WHILE FILLING)
13HEATING FAILURE (WHILE HEATING)
14HEATING TIME FAILURE (WHILE HEATING)
15TO HOT (WHILE HEATING)
16COIN BLOCKING 1 (BEFORE START UP)
17COIN BLOCKING 2 (BEFORE START UP)
18TH OVERCURRENT SECURITY (MOTOR CONTACTOR ON)
19M1 WASH PLUS LOW SPIN MOTOR SECURITY (MOTOR CONTACTOR ON)
20M2 DISTRIBUTION PLUS HIGH SPIN MOTOR SECURITY (MOTOR CONTACTOR ON)
21OVERFLOW FAILURE (WASH STEP)
22FLUSH FAILURE (FLUSH STEP)
23DEFECTIVE PCB TEMPERATURE SENSOR (ANYTIME)
24 DEFECTIVE LEVEL SENSOR (BEFORE START UP)
25DEFECTIVE TEMPERATURE SENSOR (BEFORE START UP)
26UNDERFINED FREQUENCY INVERTER ERROR CODE (WHOLE CYCLE)
27COMMUNICATION FAULT INVERTER (WHOLE CYCLE)
28THT TIME OUT (AT SPIN SEQUENCE)
29OV3 TIME OUT (AT SPIN SEQUENCE)
30ALARM FREQUENCY INVERTER (WHOLE CYCLE)
31INITIALISATION FAULT INVERTER (AT INITALISATION)
32VERIFICATION FAULT INVERTER (AT LOADING PARAMETERS)
33STALL PREVENTION FUNCTION ACTIVE (AT SPIN SEQUENCE)
34ALL PROGRAMS BLOCKED (AT BLOCKING PROGRAMS)
35WRONG SOFTWARE VERSION (NEW SOFTWARE VERSION)
36DEFECTIVE MOTOR CONTACTOR (AT TUMBLE SEQUENCE)
37DOOR UNLOCK FAULT(ONLY WDH) (END CYCLE)
38DEFECTIVE TACHO (ONLY WDH) (WHOLE CYCLE)
39DEFECTIVE SR DRIVE(ONLY WDH) (ANYTIME)
40-49MEMORY ERRORS (ANYTIME)
50NO NETWORK CONNECTION (DATA TRANSFER NETWORKING INTERRUPTED)
60NO RESET DRIVE (ONLY WDH) (WHOLE CYCLE)
61EXTENDED SPEED (ONLY WDH) (WHOLE CYCLE)
62CONTINUE SPIN (ONLY WDH) (WHOLE CYCLE)
70-88SOFTWARE ERRORS (ANYTIME)